| Sign In | Join Free | My wpc-board.com |
|
Brand Name : MINGYANG
Model Number : MY-2571A
Place of Origin : Hubei, China
MOQ : 1
Price : 180usd
Payment Terms : L/C,D/A,D/P,T/T,Western Union
Supply Ability : 1000pcs/month
Delivery Time : 1 week
Packaging Details : carton
Measuring Range : 1-1999μΩ
Accuracy Class : 0.5%
Operating Temperature : -10℃~40℃
Time Resolution : 1s
Current Resolutio : 1μΩ
Resolution : 1μΩ
Measurement accuracy : 0.5%
Measurement range : 1-1999μΩ
Working power supply : AC220V ± 10%, 50Hz ± 1Hz
Weight : 12kg
Display mode : three-and-a-half-digit LCD
Volume : 380*350*260 mm
Warranty : 2 years
Power : Electronic
Customized support : OBM, ODM, OEM, Software Reengineering
Ambient temperature and humidity : 23℃±5℃,below 75%rh
Interference voltage : <20V(should avoid)
Electrode spacing when measuring R : a>5d
Power supply : 1.5V(LR14)6 alkaline batteries
Interference current : <2A(should avoid)
Measure p Hourly electrode spacing : a>20h
Short circuit test current : AC > 20mA (sine wave)
Test frequency : 128Hz
Open circuit test voltage : AC 28V max
The grounding resistance soil resistivity tester, also known as the four-wire grounding resistance tester or soil resistivity tester, is a common instrument for testing and measuring grounding resistance. It features a super large LCD gray-white screen backlight display and microprocessor technology, utilizing microprocessor-controlled 2-wire, 3-wire, and 4-wire methods for grounding resistance testing and soil resistivity testing.
This instrument gathers multiple grounding test functions and can quickly and comprehensively measure various parameters in grounding networks. As a new generation of grounding measurement instrument that replaces traditional measurement methods, it is widely used in telecommunications, power systems, meteorology, machine rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, and more. The instrument is characterized by accurate, fast, simple, stable, and reliable testing performance.
| Measurement Function | Measurement Range | Accuracy | Resolution |
|---|---|---|---|
| Earth Resistance (R) | 0.00Ω~30.00Ω | ±2%rdg±5dgt (note 1) | 0.01Ω |
| 30.0Ω~300.0Ω | ±2%rdg±3dgt | 0.1Ω | |
| 300Ω~3000Ω | ±2%rdg±3dgt | 1Ω | |
| 3.00kΩ~30.00kΩ | ±2%rdg±3dgt | 10Ω | |
| Soil Resistivity (ρ) | 0.00Ωm~99.99Ωm | ρ=2πaR (note 2) | 0.01Ωm |
| 100.0Ωm~999.9Ωm | ρ=2πaR (note 2) | 0.1Ωm | |
| 1000Ωm~9999Ωm | ρ=2πaR (note 2) | 1Ωm | |
| 10.00kΩm~99.99kΩm | ρ=2πaR (note 2) | 10Ωm | |
| 100.0kΩm~999.9kΩm | ρ=2πaR (note 2) | 100Ωm | |
| 1000kΩm~9999kΩm | ρ=2πaR (note 2) | 1kΩm | |
| Earth Voltage | AC 0.00~600V | ±2%rdg±3dgt | 0.01V |



|
|